Troubleshooting Ascaso Steel DUO Pump Vibration Noise
Process for fixing loud Ascaso DUO Pump vibration noise during operation
Here are directions and some photos of how to access the steam pump to reposition and
correct the vibration noise.
Step 1: remove the top panel screws (with 2.5mm metric allen key) (*guide for top panel removal is here for reference *)

Step 2: - remove the ground wire from the top panel

Step 3: - Then remove 3 screws from the back panel, side panel and inner panel


Step 
Step 4: - then remove the silicone exhaust tubes x2


Step 5: - mark the water draw tubes and pull towards the front of the machine

Step 6: - disconnect the upper-left wire from the SSR

Step 7: - lift the panel out to access the steam pump and reposition in the rubber mounts
Final Steps: Carefully reassemble panels and tubing, following the guide in reverse.
** After following the guide and reassembling, if you are still having vibratory pump issues, please contact the Ascaso support team at Info@AscasoUSA.com for further assistance **